a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Measuring Tools

Fluke 9011 High-Accuracy Dual-Well Calibrator

Widest temperature range available in a single dry-well
• Combined range from –30 °C to 670 °C, one unit – two blocks
• Two independent temperature controllers (hot and cold side)
• Stability to ±0.02 °C
• Multi-hole wells for calibrating up to eight probes simultaneously

To give you the widest temperature range available in a dry-well calibrator, we’ve combined two of our most popular units. The 9011 allows temperature probes to be calibrated from –30 °C to 670 °C in a single unit.
Download
Products Lainnya
729 Automatic Pressure Calibrator
Fluke 729 Automatic Pressure Calibrator
Automatically generates and controls pressure up to 300 psi (20 bar, 2 MPa). Enter the pressure and the 729 will automatically pump to the desired pressure. Fill out the test template and the 729 will automatically pump and document pressure calibration tests at multiple points.



Easy calibration documentation using predefined templates for transmitters and switches. Enter the initial and final test pressures and the number of test points. The rest of the 729 did by documenting the applied pressure, the measured mA, and the % error of each test point. The bright color graphics display will highlight the tolerance test results in red.



Automatic fine adjustment of internal pressure helps compensate for minor leaks in hoses and test settings. There is no need to manually turn the vernier to check for leaks, helping to eliminate the hassle of manual pumping and manual fine adjustment of test settings.



HART communication allows trimming of mA output, trimming to applied value, and trimming to zero pressure from HART pressure transmitters. You can also perform light configuration tasks such as changing transmitter tags, units of measurement, and setting ranges. Other supported HART commands include setting a fixed mA output for troubleshooting, reading device configurations and variables, and reading device diagnostics.



Measures mA signal at transmitter source output and simulates mA signal for testing I/Ps and other mA loop devices. Includes a 24V loop power supply to test and power transmitters in self-tests not connected to a control system.



Rugged portable case design 3 year warranty sets the 729 apart from most other pressure calibrators. The 729 is tested and guaranteed to withstand a 1 meter drop test, making it ready for field instrumentation calibration work.



Fluke Connect® compatibility allows users to remotely monitor using the Fluke Connect mobile app as well as manage and store pressure measurements and log events. Share measurements using ShareLive™ video calls and email.



Measure temperature with the optional 720RTD probe to perform resistance transfer calibration.



Measure pressure with the old 700 Series and new 750 Series pressure modules if a different pressure measurement range or resolution is desired.



Multiple language support : select the language from the instrument setup utility. Hart communication commands are limited to English per HART device description and protocol.



The rigid yet flexible carrying case is designed for field work, with room in the bag for storing, test hoses, fittings, test cables and small tools needed for field pressure calibration.



Portable automatic pressure calibrator makes pressure calibration easy



The Fluke 729 Automatic Pressure Calibrator has been specifically designed with the work of process technicians in mind to simplify the pressure calibration process and provide faster, more accurate test results. Technicians know that calibrating pressure is a time-consuming task, but the 729 makes it easier than ever with an internal electric pump that generates and adjusts pressure automatically in a rugged, easy-to-use portable package.



The 729's ideal portable pressure calibrator, allows you to simply enter a target pressure, and the calibrator will pump automatically at the desired set point. Then, an internal fine adjustment control automatically stabilizes the pressure at the set value.



The Fluke 729 can also test multiple pressure test points automatically and automatically document the results. Calibration is as simple as entering the initial and final pressures as well as the number of test points and tolerance levels. The remaining 729 do.



Built-in HART communication capability allows for mA tuning of HART transmitters, lightweight HART configuration, and the ability to adjust to applied 0% and 100% values.



Upload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easier to manage your instrumentation, create scheduled tests and reports, and manage calibration data.



With three selectable ranges, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa), and 300 psi (20 bar, 2 MPa), the Fluke 729 Automatic Pressure Calibrator is designed to work anytime, anywhere. wherever you need it.



30 psi range, 2 bar, no wireless communication
4 13 BLADE METRIC FEELER GAUGE
Kennedy 4" 13 BLADE METRIC FEELER GAUGE
With Hardened and polished taper blades, enclosed in a steel case metric feeler blades from Kennedy are clearly marked for easy identification.



Features and Benefits

• Hardened and polished taper blades, enclosed in a steel case

• Blades are clearly marked for easy identification



Standards

• Manufactured to DIN 2275



Typical Applications

• Mechanical

• Engineering



Notes

• Range: 10 Blade: .05 - .80mm. 13 and 20 Blade: .05 - 1mm



SmartView RD Thermal Imaging Software
Fluke SmartView R&D Thermal Imaging Software
- Customizable reports - display the information you need based on your application

- Real time radiometric data streaming capability

- Data trending and time plots

- Advanced analysis features; Spot measures, lines/profiles, area/histograms, hot/cold markers, rulers, adjustable emmisivity by object, and more

- Easy to use file management
6109A  7109A Portable Calibration Baths
Fluke 6109A / 7109A Portable Calibration Baths
Key features
• Calibrate up to four tri-clamp sanitary sensors per batch with ± 0.1 °C temperature display accuracy.
• Covers a wide temperature range: 6109A: 35 °C to 250 °C
• 7109A: -25 °C to 140 °C.