Schneider miniature circuit breaker - iK60N - 1P - 40 A - C curve
This Acti9 iK60N product is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole and 40A In rated current and C tripping curve. The rated short circuit breaking capacity goes up to 6000A at 230VAC conforming to EN/IEC 60898-1 standard and at conforming to standard. This product is compliant with EN/IEC 60898-1 standard. This miniature circuit breaker protects circuit against short circuit and overload current. It has a double clip for dismounting with comb busbar in place. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 2 pitches of 9mm. The product colour is white (RAL9003). The dimensions are (W) 18mm x (H) 85mm x (D) 78.5mm. The weight is 100g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C.
Type of Luminaire : High Efficacy/Standard High Bay Set Model No : NYV20103BE1A Type of Light Source LED Power Input : 175W System Lumen Output : 25000 lm System Efficacy : 143 lm/W Power Voltage : 220-240V Power Factor : 0.95 Lifetime : 50000H(L70) CCT : 4000K CRI : 80 Input Frequency : 50/60Hz Dimming : non-Dimmable Beam Angle : 60deg. IP Rating : 65 Ambient Temperature : -30 - 50°C Surge Protection : 10kVA Dimensions : 320mmx172mm Weight : 3.9 kg Body : ADC(Black)
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.
Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.
The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.
Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.
The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.
Type of Luminaire : High Bay Special Environment Set Model No : NNFC2004788 Type of Light Source LED Power Input : 150W System Lumen Output : 21000 lm System Efficacy : 140 lm/W Power Voltage : 220-240V Power Factor : 0.9 Lifetime : 50000H(L70) CCT : 6500K CRI : 80 Input Frequency : 50/60Hz Dimming : non-Dimmable Beam Angle : 110deg. IP Rating : 65 Ambient Temperature : -40 - 60°C Dimensions : 305mmx172mm Weight : 2.9 kg Body : ADC(Black)