With its triple IR sensor, the Dräger Flame 1750 H2 detects hydrogen-based fires. It offers you high reliability against false alarms and its good measurement performance remains even at extreme temperatures.
Fast and safe detection The Dräger Flame 1750 H2 is a triple IR flame detector. It detects hydrogen-based fires even at a greater distance. In just five seconds, it notifies you of a hydrogen fire (1-metre flame) at a distance of up to 40 metres. Due to its certified reliability, the Flame 1750 H2 meets the IEC 61508 requirements for safety integrity according to SIL 2.
The flame detector also has HART® and RS-485 interfaces and has low energy consumption.
Developed for hydrogen The Dräger Flame 1750 H2 was specially developed for the detection of hydrogen fires. Its three IR sensors measure only in the 2 to 4 μm range relevant to hydrogen flames, guaranteeing high performance and a low false alarm rate. Common sources of false alarms, such as hot CO2 or welding work, are no longer a problem for you.
Robust and durable The housing is very robust and weatherproof. To protect against icing and fogging, the window can be heated automatically. This allows you to operate the Flame 1750 H2 reliably even under extreme environmental conditions, e.g. in temperatures from -60 °C to +85 °C.
Simple verification The built-in self-test "Advanced Optical Verification" (AOV) automatically checks the electronics and optics of the Flame 1750 H2. The three-colour LED on the front allows you to quickly see the device status. Green stands for normal operation, yellow indicates an error and red signals a fire alarm.
The Dräger CDR 4500 full face mask provides together with a suitable respiratory filter an approved combination specially developed for use in civil defense and civil protection.
The Dräger Polytron® SE Ex ... DQ sensing heads are gas detectors for the continuous monitoring of flammable gases and vapours in the ambient air. Measurement is based on the heat of reaction principle where a chemical reaction takes place in a catalytic bead (also known as a pellistor) inside the sensor.
The Dräger X-plore® 9000 supplied air system is designed for light duty industrial applications that require an independent air supply. This modular system provides comfortable and reliable respiratory protection in accordance with EN 14594:05.
Get the simple, reliable gas detection you need with the Ventis MX4, a 4-gas monitor designed to be rugged yet lightweight and easy to wear. The Ventis MX4 eliminates the need for extra monitors by transitioning seamlessly from personal monitoring to confined space entry with a slide-on pump.