Fluke Ti480 PRO Infrared Camera

Increased sensitivity to visualize differences

- Capture smaller temperature differences with increased thermal sensitivity

It's easier to visualize and diagnose problems

- Images on the screen are getting sharper with better color differences

- Display deviations from standard temperature and communicate concerns to your team using multiple Delta-T markers - select one as a reference point and another to display differences

- Multiple square markers on camera - identify min/max temperature for equipment area or equipment array

- Determine heat differences more easily with the new palette and wider array of yellows and greens on screen
Download
Produk Lainnya
TiX580 Infrared Camera
Fluke TiX580 Infrared Camera
Bring out the best for work.



The Ti580 is a rugged and superbly built 640 x 480 thermal image camera. Now users can perform thermal image checks more confidently and faster than ever before - all thanks to the ruggedness and ease of use that Fluke has come to expect.



See sharper and clearer images for more accurate interpretation.



A screen that can rotate 240 degrees makes it easier to take pictures when the equipment is in an area that is difficult or not easy to reach. The ergonomic design and neck strap make long inspection days easier. Outdoors, the swivel display lets you adjust it to minimize glare, and the Fluke 5.7" touchscreen LCD offers premium viewing in the field - truly "built for a purpose."



Includes new, powerful and easy-to-use Fluke Connect® SmartView® desktop software.



The Fluke Connect SmartView desktop software is a comprehensive and connected software platform that represents the future of integrated equipment maintenance, monitoring, analysis and reporting now available. It's easier than ever to optimize thermal analysis, generate fast, customizable and powerful reports and export images to your preferred format in the cloud. And you'll be able to integrate it with Fluke Connect – the world's largest system of integrated maintenance tools and software.
190062III Color ScopeMeter 60 MHz 2 channels
Fluke 190-062-III Color ScopeMeter, 60 MHz, 2 channels
Fluke 190-062-III Offers



Accurate and versatile, this portable oscilloscope provides a fast sampling rate of up to 5 GS/s, a 200 ps resolution, and deep memory of 10,000 samples per channel. Perform timing or amplitude-related measurements on three phases or three-axis control systems, or compare and contrast multiple test points in a circuit under test.



Features

- Up to four independent floating isolated inputs, up to 1000 V

- Up to 5 GS/s real time sampling (depending on model and channels used)

- Deep memory: 10,000 points per trace waveform capture (scope mode)

- CAT III 1000 V/CAT IV 600 V safety rated instrument for industrial environments

- Up to seven hours of battery operation using BP291

- Large, bright color display is easy to view in nearly any environment

- Easy to store and view historical data and transfer to a PC via USB or Wifi

- Convenient battery access door for quick battery swaps in the field

- IP51 rating, dust and drip-proof

- Connect-and-View triggering for intelligent, automatic triggering on fast, slow and even complex signals

- Frequency spectrum using FFT-analysis

- Automatic capture and REPLAY of 100 screens

- ScopeRecord mode gives 30,000 points per input channel for low frequency signal analysis

- TrendPlot Paperless Recorder mode with deep memory for longterm automatic measurements

- 5000 count DMM included in the 2-channel models



Applications

- Microelectronics

- Troubleshooting



Measure from mV to kV safely



Independently isolated inputs allow you to make measurements in mixed circuits having different ground references reducing the risk of accidental short circuits. Conventional bench oscilloscopes without special differential probes and isolation transformers can only reference measurements to line power earth ground. ScopeMeter 190 Series III test tools are engineered to cover a wide application range from mV to kV, so you’re ready for anything from microelectronics to heavy duty higher voltage electrical applications. 190 Series III 60 MHz and 100 MHz configurations include VPS421 100:1 probes for higher voltage applications, while the 200 MHz and 500 MHz configurations include VPS410-II 10:1 probes suitable for both microelectronics and higher voltage applications.



IP-51 rated for harsh environments



Rugged and shock-proof, ScopeMeter Test Tools are built for dirty, hazardous environments. With its sealed case, it can endure dust, drips, humidity and airborne pollutants. Every time you reach for ScopeMeter Test Tool you can be confident it will work reliably wherever your work takes you.



USB and Wi-Fi connectivity



The 190 Series III offers two USB ports, electrically isolated from measurement input circuits allowing you to quickly and easily transfer data to a PC, archive and share waveforms with OEMs, colleagues and support staff, or store waveforms, screen captures and instrument setups onto USB memory devices for later use. Easily transfer saved files via USB stick, direct connection via the USB interface or optional Wi-Fi connectivity. These files can be used for further data handling or in FlukeView-2 Software to study waveforms in greater detail.



Connect-and-View triggering



Connect-and-View triggering provides an instant, stable display without the need for adjusting settings. If you’ve used other scopes, you know how tricky triggering can be. If settings are incorrect, results can be unstable or incorrect. Connect-and-View automatically sets up correct triggering by recognizing signal patterns. Without touching a button, you get a stable, reliable and repeatable display of virtually any signal including motor drive and control signals. It’s especially fast and convenient when you’re measuring a number of test points in rapid succession.



Built-in digital multimeter



Conveniently switch from waveform analysis to precise multimeter measurements using the built in 5000 count digital multimeter on two channel 190 Series III models. Measurement functions include Vdc, Vac, Vac+dc, resistance, continuity and diode test. Measure current and temperature using suitable shunt, probe or adapter with wide range of scaling factors.



TrendPlot paperless recorder— records up to 11 days to help you find intermittent faults



The toughest faults to find are those that happen only once in a while. These intermittent events can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Line outages, dips, swells and interruptions, or the starting and stopping of a motor can also cause a machine to stop. You may not be around when it happens, but the 190 Series III ScopeMeter Test Tool will be.

- Plot minimum and maximum peak values and average over time

- Plot any combination of up to four readings including voltages, amps, temperature, frequency and phase for all inputs, all with time and date stamp to pinpoint faults
6150mm COOLANTPROOF IP 67 DIGITAL CALIPER
Kennedy 6"/150mm COOLANT-PROOF IP 67 DIGITAL CALIPER
Available in a range of sizes, this digital caliper is coolant, water and dust proof to IP67 level. It has a large LCD display, fast response speed, dual readout (mm/inch) and can be used for inside, outside, depth and step measuring. Also enables absolute and relative reading.



Extra batteries available - Order Code PAN9042505E 3V Lithium Metal cell
ii910 Precision Acoustic Imager
Fluke ii910 Precision Acoustic Imager
Finally, there is an easy way to detect, locate and analyze partial discharges in one tool



Tired of spending too much time detecting partial discharges? Introducing the i910 Precision Acoustic Imger which is designed to find partial discharges, corona discharges, and gas and vacuum leaks. The ii910 acoustic imaging camera's breakthrough technology is a cost-efficient, safe, effective, and easy tool for teams inspecting and maintaining power distribution and industrial high-voltage equipment.



The invisible threat….now you can see it



Partial discharge is a serious issue that the team monitors on a daily basis. When scanning insulators, transformers, medium-voltage panels (switchgear), or high-voltage power lines, you need to be sure that you find the problem early and quickly. Undetected partial discharges can cause power outages, fires, explosions, or death from electric arcing. In addition to these hazards threatening the environment and human life, electric arcing can also cause costly losses. Equipment failure can cost millions of dollars per hour and research shows that a data center outage can cost as much as $8,851 per minute. Ultimately, the Department of Energy estimates that these outages cost the US economy $150 billion annually.



Important area to scan Partial Discharge

- Insulator

- Transformer

- High voltage power cable

- Medium voltage panels

- Lightning rod

- Busbar

- High voltage coil

- circuit breaker

- capacitor



Do it quickly and safely



The ii910 is the All-in-One tool you've been looking for for all your Leakage and Discharge problems. Everything you need is at your fingertips. Perform quick area or neighborhood scans and get all the pictures/video you need using simple one-button shooting and the large 7” touchscreen LCD. No need for additional tools or equipment. Without the need for complicated cables or secondary devices, you have full mobility and greater flexibility to switch between leak/partial discharge detection and repair of partial leak/discharge.



Fluke safety you can count on with performance you value



The Fluke ii910 Precision Acoustic Imager is the perfect tool for high-voltage electricians, electrical test technicians, and grid maintenance teams who constantly inspect and maintain power distribution and industrial high-voltage equipment. The ii910 provides a safe and fast way to detect and locate partial discharges to maintain high-voltage equipment and prevent catastrophic events. With SoundSight™ technology, the ii910 translates the sounds it hears into a visual representation so you can quickly find problem areas. The higher frequency capability of the ii910 enables early detection to facilitate earlier maintenance planning, which is why the ii910 has a frequency range of 2-100 kHz.



Find and repair them before the arc of fire appears



Partial discharges can cause a number of serious and costly problems ranging from severe equipment damage to lethal arcing. The only way to stop this from happening is to properly inspect and maintain the equipment. The ii910 Precision Acoustic Imager is built to make partial discharges faster and easier to find. Gone are the days of wearing headphones and listening to very faint or faint sounds on the tiny screen to find problems. Everything you need to remotely troubleshoot is right there in the ii910, without dangling and tangling cables or other accessories. Just pick it up, turn it on, and start troubleshooting.



The security you expect from a tough product you trust



Safety is key when working on high voltage equipment and at Fluke, safety is important, everything else is just a bonus. Due to a combination of special microphone positions and advanced algorithms the ii910 Acoustic Acoustic Imager can detect Partial Discharges and Corona Discharges from a distance of 120 meters. This means you can be farther away than necessary and still be effective and efficient in finding all of the problem areas. With no external cables or corner adjustment accessories, the ii910 ensures you don't get stuck in your gear while you work. In addition to acoustic imaging technology capable of capturing reflected sound, you don't even need a direct line of sight to spot a problem. This means you can find partial discharges without ever opening the cabinet.



Quickly find it easily without training



The ii910 is truly designed so that anyone can use it with little or no training. There's no need for certification anymore as you don't need one to operate this tool. Simply power on the ii910 with a single button, select a frequency range or let the tool do the work for you, and begin scanning immediately for partial discharges or leaks. Once you find a sound image, you can take a video or photo for later use after you've added text annotations. If you want to know more about a specific leak or partial discharge, turn to PDQ or LeakQ.