a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Measuring Tools

Fluke ACDC-54NAV 1000 A AC/DC Navigator Clamp Meter with Temperature

The ACDC-54NAV clamp-on power meter offers AC/DC current measurements to 1000 A, AC/DC voltage to 1000 V, temperature capabilities, and wide jaws to handle large conductors up to 1.6″ (40 mm) for high voltage industrial environments.



This clamp-on multimeter offers a full range of power quality diagnostics including power and power factor, total harmonics distortion, individual harmonics, in-rush current, phase sequence, TRMS and low pass filter for industrial power monitoring and verifying system conditions.
Download
Produk Lainnya
Fluke ii915 Acoustic Imager
Fluke Fluke ii915 Acoustic Imager
Fluke ii915 Acoustic Imager: Detect, Locate, and Assess Anomalies

The Fluke ii915 Acoustic Imager is a powerful tool designed to identify and evaluate issues in various systems. With three distinct modes—LeakQ™, PDQ™, and MecQ™—this innovative device empowers maintenance professionals to take proactive measures and prevent costly problems. Let’s explore its capabilities:

Leak Detection with More Sensitivity
LeakQ™ Mode: Detect Hidden Costs


Leaks in compressed air, gas, steam, and vacuum systems can lead to significant financial losses. The Fluke ii915 simplifies leak detection by allowing technicians to visualize sound. As they scan hoses, fittings, and connections, the built-in acoustic array captures decibel levels per frequency. The resulting SoundMap™ overlays on a visual image, making it easy to pinpoint leaks—even during peak operation hours. Say goodbye to time-consuming inspections and hello to efficient leak detection. Fluke ii915 has the high frequency range and best sensitivity to do acoustic leak detection more efficiently.

Early Mechanical Issue Identification
MecQ™ Mode: Efficient Inspection for Conveyor Systems


Conveyor systems are notorious for their complexity and potential to disrupt production. The Fluke ii915 acoustic camera revolutionizes inspection by enabling contactless scanning of large areas. Advanced noise filtering ensures clear images, even in high-noise environments. Detecting potential mechanical issues early allows targeted maintenance, preventing unplanned downtime. For seamless operation and proactive maintenance of large conveyance systems, the Fluke ii915 Acoustic Imager with MecQ™ is the ultimate choice.

Visualizing the Invisible Threat
PDQ™ Mode: Locating Partial Discharge


Partial discharge poses serious risks, from arc flash fires to blackouts. The Fluke ii915 translates partial discharge sounds into visuals, precisely pinpointing their location. With an extended frequency range of 2-100 kHz, this tool can detect partial discharge even earlier and aids maintenance planning to prevent catastrophic events. High-voltage electricians, electrical test engineers, and grid maintenance teams can now see what was once invisible.

Key features
• Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
• LeakQ™ Mode: Estimated leak size and cost.
• PDQ Mode™: Assesses discharge severity.
• MecQ™ Mode: Proactively address potential problems in rotating mechanical components.
• Reporting Features: Integrated visual and textual tagging and annotation functionalities for streamlined reporting.
• Wireless Upload: Easily transfer data to Fluke Connect.
54 II B Data Logging Thermometer with Dual Input
Fluke 54 II B Data Logging Thermometer with Dual Input
The Fluke 50 Series II contact thermometer offers fast response and laboratory accuracy (0.05% + 0.3°C) in a rugged hand test kit.
T51000 Voltage Continuity and Current Tester
Fluke T5-1000 Voltage, Continuity and Current Tester
• OpenJaw™ design: measure current without breaking the circuit

• Tester automatically selects AC or DC voltage, up to 1000 V

• Work in tight spaces with detachable Slim Reach probe tips
9132 and 9133 Portable Infrared Calibrators
Fluke 9132 and 9133 Portable Infrared Calibrators
Precision when you need it for infrared temperature calibration

Fluke 9132 and Fluke 9133 Portable Infrared Calibrators features:
• Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)
• Large 57 mm (2.25 in) blackbody target
• RTD reference well for contact temperature measurement
• Small, compact design in a blackbody calibrator

Whether you’re using in-line or handheld infrared pyrometers, you need good calibration standards to verify their accuracy. Our portable IR calibrators provide stable blackbody targets for calibrating noncontact IR thermometers from –30 °C to 500 °C.

These blackbody calibrator units feature a temperature controlled measurement surface with a diameter of 2.25 in (57 mm). The target temperature can be controlled in set-point increments of 0.1° from –30 °C to 500 °C and a well is located directly behind the blackbody surface for contact temperature measurement.