a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Measuring Tools

Kennedy 28 BLADE SCREW PITCH GAUGE 55 DEG WHIT

Ideal for accurately measuring internal and external thread forms. Manufactured from hardened and polished steel, the blades are precision milled for optimum accuracy. Enclosed in a steel case.



Featrures and Benefits

• Hardened and polished steel for increased durability

• With precision milled blades for accuracy

• Used to internal and external thread forms

• Enclosed in a steel case for easy storage and portability
Download
Produk Lainnya
1587 FC Insulation Multimeter
Fluke 1587 FC Insulation Multimeter
Keep yourself safe. Find hidden problems faster. Put the paperwork down.



Fluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance.



Add diagnostics with Fluke Connect

The Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions, including:

- Safety first. Keep yourself out of harm’s way by monitoring your test measurements remotely.

- Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.

- Quickly find problems by saving and comparing measurements over time on a wireless device.

- PI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster

- Memory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time

- Temperature compensation to establish accurate baselines and relevant historical comparisons

- Historical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately)

- Provides memory storage through Fluke Connect Measurements to eliminate the need to write down results

- Includes live circuit detection to prevent insulation test if voltage >30 V is detected

- Supports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect® Assets (sold separately)

- Incorporates VFD low-pass filter for accurate variable frequency motor drive measurements

- Includes auto-discharge of capacitive voltage for added user protection

- Measures ac/dc voltage, dc millivolts, ac/dc milliamps, resistance, and continuity

- Includes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing reading

- Automatically powers off to save battery power

- Comes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty.
ii910 Precision Acoustic Imager
Fluke ii910 Precision Acoustic Imager
Finally, there is an easy way to detect, locate and analyze partial discharges in one tool



Tired of spending too much time detecting partial discharges? Introducing the i910 Precision Acoustic Imger which is designed to find partial discharges, corona discharges, and gas and vacuum leaks. The ii910 acoustic imaging camera's breakthrough technology is a cost-efficient, safe, effective, and easy tool for teams inspecting and maintaining power distribution and industrial high-voltage equipment.



The invisible threat….now you can see it



Partial discharge is a serious issue that the team monitors on a daily basis. When scanning insulators, transformers, medium-voltage panels (switchgear), or high-voltage power lines, you need to be sure that you find the problem early and quickly. Undetected partial discharges can cause power outages, fires, explosions, or death from electric arcing. In addition to these hazards threatening the environment and human life, electric arcing can also cause costly losses. Equipment failure can cost millions of dollars per hour and research shows that a data center outage can cost as much as $8,851 per minute. Ultimately, the Department of Energy estimates that these outages cost the US economy $150 billion annually.



Important area to scan Partial Discharge

- Insulator

- Transformer

- High voltage power cable

- Medium voltage panels

- Lightning rod

- Busbar

- High voltage coil

- circuit breaker

- capacitor



Do it quickly and safely



The ii910 is the All-in-One tool you've been looking for for all your Leakage and Discharge problems. Everything you need is at your fingertips. Perform quick area or neighborhood scans and get all the pictures/video you need using simple one-button shooting and the large 7” touchscreen LCD. No need for additional tools or equipment. Without the need for complicated cables or secondary devices, you have full mobility and greater flexibility to switch between leak/partial discharge detection and repair of partial leak/discharge.



Fluke safety you can count on with performance you value



The Fluke ii910 Precision Acoustic Imager is the perfect tool for high-voltage electricians, electrical test technicians, and grid maintenance teams who constantly inspect and maintain power distribution and industrial high-voltage equipment. The ii910 provides a safe and fast way to detect and locate partial discharges to maintain high-voltage equipment and prevent catastrophic events. With SoundSight™ technology, the ii910 translates the sounds it hears into a visual representation so you can quickly find problem areas. The higher frequency capability of the ii910 enables early detection to facilitate earlier maintenance planning, which is why the ii910 has a frequency range of 2-100 kHz.



Find and repair them before the arc of fire appears



Partial discharges can cause a number of serious and costly problems ranging from severe equipment damage to lethal arcing. The only way to stop this from happening is to properly inspect and maintain the equipment. The ii910 Precision Acoustic Imager is built to make partial discharges faster and easier to find. Gone are the days of wearing headphones and listening to very faint or faint sounds on the tiny screen to find problems. Everything you need to remotely troubleshoot is right there in the ii910, without dangling and tangling cables or other accessories. Just pick it up, turn it on, and start troubleshooting.



The security you expect from a tough product you trust



Safety is key when working on high voltage equipment and at Fluke, safety is important, everything else is just a bonus. Due to a combination of special microphone positions and advanced algorithms the ii910 Acoustic Acoustic Imager can detect Partial Discharges and Corona Discharges from a distance of 120 meters. This means you can be farther away than necessary and still be effective and efficient in finding all of the problem areas. With no external cables or corner adjustment accessories, the ii910 ensures you don't get stuck in your gear while you work. In addition to acoustic imaging technology capable of capturing reflected sound, you don't even need a direct line of sight to spot a problem. This means you can find partial discharges without ever opening the cabinet.



Quickly find it easily without training



The ii910 is truly designed so that anyone can use it with little or no training. There's no need for certification anymore as you don't need one to operate this tool. Simply power on the ii910 with a single button, select a frequency range or let the tool do the work for you, and begin scanning immediately for partial discharges or leaks. Once you find a sound image, you can take a video or photo for later use after you've added text annotations. If you want to know more about a specific leak or partial discharge, turn to PDQ or LeakQ.
HD160C Heavy Duty TRMS Multimeter with Temperature
Fluke HD160C Heavy Duty TRMS Multimeter with Temperature
The Amprobe HD160C Heavy Duty Multimeter is designed for professional use in harsh environments. Its made using waterproof construction to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts.



Built with tough, fire-retardant thermoplastic that is resistant to grease and chemical spills and with shock-mounted components that are drop resistant to at least 8 feet, the Amprobe HD160C is unusually rugged and reliable. It has an extended voltage measurement capability of 1500 V DC and 1000 V AC, unmatched by any other line of digital multimeters. The extended voltage ranges can withstand transients up to 12 kV, and it also measures temperature.
MDA550 Series III Motor Drive Analyzer
Fluke MDA-550 Series III Motor Drive Analyzer
Simplify complex motor drive troubleshooting with guided test setups and automatic drive measurement that provide reliable, repeatable test results.

The Fluke MDA 550 Motor-Drive Analyzer saves time and the hassle of setting up complex measurements, and simplifies the troubleshooting process. Simply select a step-by-step guided test and measurement will show you where to make voltage and current connections, while preset measurement profiles ensure you will get all the data you need for every critical motor drive part, from input to output, the DC bus, and the motor itself . Doing simple to complex measurements? MDA-550 can do it. What's more, making reports before (as-found) and after (as-left) repairs or adjustments becomes more practical. This is all thanks to its built-in report generator feature.



The MDA-550 is an ideal portable motor drive analysis testing tool. Not only that, this tool can also be used to safely detect and solve common problems in inverter-type motor drive systems.



- Measures main motor drive parameters , including voltage, current, DC bus voltage level and AC ripple, voltage and current unbalance and harmonics, voltage modulation, and motor shaft voltage discharge.

- Performs broader harmonic measurements to identify the impact of low and high order harmonics on your power system.

- Performs guided measurements of motor drive input, DC bus, drive output, motor input, and shaft measurements with step-by-step graphical diagrams of voltage and current connections.

- Uses simple measurement settings with preset measurement profiles to automatically trigger data collection based on the selected test procedure.

- Quickly and easily generate reports that are perfect for documenting problem solving and collaborative work with others.

- Measure additional electrical parameters with a complete 500 MHz oscilloscope, meter and logger capability for a wide range of electrical and electronic measurements in industrial systems



The Fluke MDA-550 Motor Drive Analyzer uses guided test measurements to make analysis even easier



Drive input



Quickly measure input voltage and current to see if values ??are within acceptable limits by comparing the rated voltage to the actual supply voltage. It then checks the input current to determine if the current is within its maximum rating and the conductor size is appropriate. You can also check if the harmonic distortion is within an acceptable level. There are two options for doing this: carefully examine the shape of the waveform or look at the harmonics spectrum screen which displays total harmonic distortion and individual harmonics.



Imbalance of voltage and current



Check the voltage unbalance at the input terminals so you can make sure the voltage unbalance is not too high (> 6-8%), and the phase rotation is correct. You can also check for current unbalance, as too large an imbalance can indicate a driving rectifier problem.



Wider harmonic measurement



Excess harmonics are not only a threat to your rotating machine, but also to other equipment connected to the mains power system. As well as being able to detect motor drive harmonics, the MDA-550 can also detect the potential impact of inverter switching electronics. The MDA-550 has three harmonic ranges, 1st to 51st harmonics, 1 to 9 kHz, and 9 kHz to 150 kHz providing the ability to detect harmonic pollution problems.



Bus DC



In motor drives, the conversion of AC to DC inside the drive is very important. The reason is that for the best drive performance it is necessary to have the right voltage and adequate smoothing with low ripple. High ripple voltages can be an indicator of a faulty capacitor or a faulty motor connected. The logging function can be used to dynamically check the performance of the DC bus in operating mode when load is applied.



Drive output



Check drive output focusing on voltage to frequency (V/F) ratio, and voltage modulation. If the V/F ratio is high, the motor may overheat. With a low V/F ratio, the connected motor may not be able to provide the torque required at the load to carry out the process for which it is intended.



Voltage modulation



Pulse Width Modulation signal measurements are used to check for high voltage peaks that can damage motor winding insulation. The rise time or steepness of the impulse is indicated by a dV/dt reading (value of change in voltage over time), this must be compared with the specified motor insulation. Metering can also be used to measure switching frequency. Its purpose is to detect whether there is a potential problem with the switching electronics, or with grounding, as the signal drifts up and down.



Input Motor



Ensuring the supply of voltage at the motor input terminal is important. However, choosing a connecting cable between the drive and the motor is no less important. Incorrect cable selection can cause damage to the drive and motor due to overvoltage peaks. Checking that the current at the terminals is within the motor's rating is critical because excess current can cause the motor to overheat, reducing the life of the stator insulation which can cause premature failure of the motor.



Motor shaft voltage



The voltage impulse in the variable speed drive is generated from the circuit between the motor stator and the rotor until a voltage appears on the rotor shaft. If the rotor shaft voltage exceeds the insulating capacity of the bearing grease, flashover currents (glow) may occur. As a result, pitting and fluting of the motor bearing rotation occurs, namely damage that causes the motor to fail prematurely. The MDA-550 is equipped with a carbon fiber brushed probe tip that makes it easy for you to detect destructive flashover currents. Meanwhile, the amplitude of the impulse and the number of events can be used as a consideration in taking preventive action. With the addition of these accessories and capabilities, you can spot potential faults without the need to buy expensive permanent solutions.



Step-by-step guided measurements ensure you have the data you need, when you need it



The MDA-550 is designed to help you quickly and easily test and troubleshoot common three-phase and single-phase inverter-type motor drive systems. Onscreen information and a step-by-step setup guide make it easy for you to configure the analyzer. Not only that, the information and guide will also provide the required drive measurements. That way, you can quickly make informed decisions regarding maintenance. From power input to attached motor, the MDA-550 provides measurement capabilities for the fastest motor drive solutions.