Fluke 1760TR Three-Phase Power Quality Recorder

The Fluke 1760 Three-Phase Power Quality Recorder complies strictly with IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent conformity testing. Designed for the analysis of utility and industrial power distribution systems, in medium and low voltage networks, these power quality monitors give customers the flexibility to customize threshold selection, algorithms and measurements. The Fluke 1760 power recorder records the most thorough detail for user-selected parameters.



Usage



Detailed fault analysis – Performs high-speed transient analysis and finds root causes of equipment malfunctions for later mitigation of malfunctions and predictive maintenance. The fast transient option, with a measuring range of 6,000 V, makes it possible to record very short impulses such as lightning strikes.



Class-A Quality of Service Compliance – Validates the quality of incoming power at the service gateway. Thanks to Class A conformance, the Fluke 1760 allows unquestioned verification.



Correlation of events at multiple locations – Using GPS time synchronization, users can quickly detect where a fault first occurred, both inside and outside the facility.



Galvanic separation and DC coupling – Allows complete measurement of dissimilar power systems. For example, troubleshooting a UPS system by simultaneously recording battery voltage and power output.



Power quality and power load monitoring – Assess baseline power quality to validate compatibility with critical systems prior to installation and verify electrical system capacity before increasing loads.
Download
Produk Lainnya
28 II Ex Intrinsically Safe Truerms Digital Multimeter
Fluke 28 II Ex Intrinsically Safe True-rms Digital Multimeter
Now there is one intrinsically safe digital multimeter (DMM) you can use in IIC (gas), in Zones 1 and 2, and IIIC (dust), Zones 21 and 22. Whether you work in an oil, chemical, or pharmaceutical environment , all the test and troubleshooting capabilities you need are in the most robust and intrinsically secure (IS) Fluke DMM ever made. The Fluke 28 II Ex is also water, dust and drop resistant. You will be equipped to solve all problems, inside and outside the danger zone, without compromising on compliance or measurement performance.
11280mm VERNIER CALIPER
Kennedy 11"/280mm VERNIER CALIPER
Metric & Inch Reading - Graduation: 0.02mm/0.001"

Incorporating Quadri feature - gives outside, inside, depth and step readings.

Fine adjustment feature allows improved sensitivity of slider movement.

14° vernier face angle reduces parallax.



Satin chrome finish with clear easy read graduations.



300mm12 RIGID RUSTLESS RULE ROUND END
Kennedy 300mm/12" RIGID RUSTLESS RULE ROUND END
Our Kennedy® rigid steel rulers are made from the finest quality spring-tempered stainless steel and finished in satin chrome. They're flexible and durable with an anti-glare finish for use in any environment.



Features and Benefits

• Anti-glare finish for easy reading in all lighting levels

• Permanent black figures and graduations allow for precise measurements

• Round end complete with hanging hole for easy storage

• Anti-rust for product longevity



Standards

• BS 4372:1968
4180 4181 Precision Infrared Calibrators
Fluke 4180, 4181 Precision Infrared Calibrators
Accuracy and traceability for infrared measurements

Now it’s easy to increase your IR temperature measurement accuracy with the new 4180, 4181 Precision Infrared Calibrators from Fluke Calibration. These infrared temperature calibrators give more consistent, accurate and reliable calibrations because emissivity is radiometrically calibrated, and the target size minimizes size of source effect errors. In addition, these infrared calibrators simplify calibration because they uniquely compensate for errors caused by thermometer emissivity settings.

New accredited performance for point-and-shoot calibrations
• Calibrated radiometrically for meaningful, consistent results.
• Accredited calibration included
• Accurate, reliable performance from –15 °C to 500 °C
• Large target size of 152 mm (6 in) is required for calibrating most thermometers.
• Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
• Intuitive, easy-to-read display that indicates when temperature is stable.