Type of Luminaire : Standard Floodlight (Pro) A Series Set Model No : NYS12347LD2031 Type of Light Source : LED Power Input : 264W System Lumen Output : 41000 lm Power Voltage : 200-242V Lifetime : 40000H(L70) CCT : 5000K CRI : 70 Input Frequency : 50/60Hz Dimming : non-Dimmable Glare Cut Angle : 60deg. Beam Angle : 54deg. IP Rating : 75deg. Ambient Temperature : -20 - 35°C Dimensions : 422mmx534mmx340mm Body : ADC
Type of Luminaire : Standard Floodlight (Pro) A Series Set Model No : NNP19940031 Type of Light Source : LED Power Input : 120W System Lumen Output : 15600 lm Power Voltage : 110-240V Lifetime : 50000H(L70) CCT : 5000K CRI : 70 Input Frequency : 50/60Hz Dimming : non-Dimmable Glare Cut Angle : 60deg. Beam Angle : 60deg. IP Rating : 65 Ambient Temperature : -40 - 50°C Dimensions : 304mmx310mmx296mm Body : ADC
Type of Luminaire : Standard Floodlight (Pro) A Series Set Model No : NYS12847LD2031 Type of Light Source : LED Power Input : 783W System Lumen Output : 122300 lm Power Voltage : 200-242V Lifetime : 40000H(L70) CCT : 5000K CRI : 70 Input Frequency : 50/60Hz Dimming : non-Dimmable Glare Cut Angle : 54deg. Beam Angle : 34deg. IP Rating : 65 Ambient Temperature : -20 - 35°C Dimensions : 487mmx537mmx720mm Body : ADC
Type of Luminaire : Dimmable High Bay Set Model No : NNFC20540DZ88 Type of Light Source : LED Power Input : 85W System Lumen Output : 11900 lm System Efficacy : 140 lm/W Power Voltage : 220-240V Power Factor : 0.9 Lifetime : 50000H(L70) CCT : 6500K CRI : 80 Input Frequency : 50/60Hz Dimming : Dimmable Dimming Range : 5-100% Beam Angle : 60deg. IP Rating : 65 Ambient Temperature : -30 - 50°C Dimensions : 260mmx154mm Weight : 2.1 kg Body : ADC
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.
Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.
The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.