a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Electrical & Lighting

Panasonic NNP11740GL

Type of Luminaire : Street Light EVO
Set Model No : NNP11740GL
Type of Light Source : LED
Power Input : 40W
System Lumen Output : 5200 lm
Power Voltage : 100-240V
Power Factor : 0.90
Lifetime : 50000H(L70)
CCT : 5000K
CRI : 70
Input Frequency : 50/60Hz
Dimming : 5 steps automatic dimming
IP Rating : 66
Ambient Temperature : 5°C~40°C
Dimensions : 564×157×101mm
Body : ADC
Download
Produk Lainnya
NNFC20540DZ88
Panasonic NNFC20540DZ88
Type of Luminaire : Dimmable High Bay
Set Model No : NNFC20540DZ88
Type of Light Source : LED
Power Input : 85W
System Lumen Output : 11900 lm
System Efficacy : 140 lm/W
Power Voltage : 220-240V
Power Factor : 0.9
Lifetime : 50000H(L70)
CCT : 6500K
CRI : 80
Input Frequency : 50/60Hz
Dimming : Dimmable
Dimming Range : 5-100%
Beam Angle : 60deg.
IP Rating : 65
Ambient Temperature : -30 - 50°C
Dimensions : 260mmx154mm
Weight : 2.1 kg
Body : ADC
miniature circuit breaker  iK60N  1P  40 A  C curve
Schneider miniature circuit breaker - iK60N - 1P - 40 A - C curve
This Acti9 iK60N product is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole and 40A In rated current and C tripping curve. The rated short circuit breaking capacity goes up to 6000A at 230VAC conforming to EN/IEC 60898-1 standard and at conforming to standard. This product is compliant with EN/IEC 60898-1 standard. This miniature circuit breaker protects circuit against short circuit and overload current. It has a double clip for dismounting with comb busbar in place. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 2 pitches of 9mm. The product colour is white (RAL9003). The dimensions are (W) 18mm x (H) 85mm x (D) 78.5mm. The weight is 100g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C.
NYV20150BE2A
Panasonic NYV20150BE2A
Type of Luminaire : High Efficacy/Standard High Bay
Set Model No : NYV20150BE2A
Type of Light Source LED
Power Input : 75W
System Lumen Output : 10710 lm
System Efficacy : 143 lm/W
Power Voltage : 220-240V
Power Factor : 0.95
Lifetime : 50000H(L70)
CCT : 5000K
CRI : 80
Input Frequency : 50/60Hz
Dimming : non-Dimmable
Beam Angle : 60deg.
IP Rating : 65
Ambient Temperature : -30 - 50°C
Surge Protection : 10kVA
Dimensions : 240mmx166mm
Weight : 1.99 kg
Body : ADC(Black)
ACB 3200A 3P 66kA
Siemens ACB 3200A 3P 66kA
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.

Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.

The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.