Panasonic NNFC2009388

Type of Luminaire : High Bay Special Environment
Set Model No : NNFC2004388
Type of Light Source LED
Power Input : 200W
System Lumen Output : 28000 lm
System Efficacy : 140 lm/W
Power Voltage : 220-240V
Power Factor : 0.9
Lifetime : 50000H(L70)
CCT : 5000K
CRI : 80
Input Frequency : 50/60Hz
Dimming : non-Dimmable
Beam Angle : 110deg.
IP Rating : 65
Ambient Temperature : -40 - 60°C
Dimensions : 345mmx182mm
Weight : 3.2 kg
Body : ADC(Black)
Download
Produk Lainnya
Inspection Light LED Rechargeable 320lm IP20
Edison Inspection Light, LED, Rechargeable, 320lm, IP20
Comprises of 2 lights - COB as lamp and 7 LED lights on the top. Magnetic base and back, x2 360˚ swivel and foldaway hanging hooks. IP20. Operating time: 2 - 2.5 hrs (high mode), 4 - 4.5 hrs (low mode), 10 hrs (top LEDs). Charge time: 4 - 5 hrs.

Features and Benefits
• Ultra-bright for enhanced luminosity
• Efficient yet effective
• Foldaway hanging hooks for convinience

Notes
• 320 Lumens
• Run time: up to 2.5hrs (high mode COB)
• Run time: up to 4.5hrs (low mode COB)
• Run time: up to 10 hrs (top LEDs)
• Max. charging time: 5hours
• IP20
Head Torch LED NonRechargeable 35lm 20m Beam Distance IPX4
Edison Head Torch, LED, Non-Rechargeable, 35lm, 20m Beam Distance, IPX4
Highly efficient, sturdy headband torch with four different operating modes. Perfect for a wide range of applications where effective hands-free lighting is required.

Features and Benefits
• Four lighting modes: 4 LED's on (power saving mode), 8 LED's on, 12 LED's on, 12 LED's flashing
• Headlamp body tilts up to 90 degrees
• Impact resistance (drop test) 1m for resilience
• Operating temperature of -20 - 50°C for versatility in use
• IPX-4 waterproof and designed for use outdoors in heavy rain

Notes
• Requires 3x AAA batteries (not included)

miniature circuit breaker  iK60N  3P  6 A  C curve
Schneider miniature circuit breaker - iK60N - 3P - 6 A - C curve
This Acti9 iK60N product is a low voltage miniature circuit breaker (MCB). It is a 3P circuit breaker with 3 protected poles and 6A In rated current and C tripping curve. The rated short circuit breaking capacity goes up to 6000A at 400VAC conforming to EN/IEC 60898-1 standard and at conforming to standard. This product is compliant with EN/IEC 60898-1 standard. This miniature circuit breaker protects circuit against short circuit and overload current. It has a double clip for dismounting with comb busbar in place. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 400VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 6 pitches of 9mm. The product colour is white (RAL9003). The dimensions are (W) 54mm x (H) 85mm x (D) 78.5mm. The weight is 300g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C.
ACB 1000A 3P 55kA
Siemens ACB 1000A 3P 55kA
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.

Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.

The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.