a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Product

Electrical & Lighting

**Jika tidak menemukan produk yang anda cari, silahkan chat admin melalui whatsapp untuk cek ketersediaan barangnya
Miniature circuit breaker Domae 2P 2 A C Curve 6000 A
Schneider Miniature circuit breaker, Domae, 2P, 2 A, C Curve, 6000 A
This Domae product is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 1 protected poles and 2A In rated current and C tripping curve. The Icn rated short circuit breaking capacity is up to 6000A at 230VAC conforming to EN/IEC 60898-1 standard. It is compliant with IEC 60898-1 standard. This miniature circuit breaker protects circuit against short circuit and overload current. Mechanical durability goes up to 20000 cycles and electrical durability goes up to 10000 cycles. The Ue operational voltage is going from 230VAC. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 4 pitches of 9mm. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 81mm x (D) 71.5mm. The weight is 0.190kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -5°C to 60°C. The storage temperature is -40°C to 85°C.
Miniature circuit breaker Domae 3P 6 A C Curve 6000 A
Schneider Miniature circuit breaker, Domae, 3P, 6 A, C Curve, 6000 A
This Domae product is a low voltage miniature circuit breaker (MCB). It is a 3P circuit breaker with 3 protected poles and 6A In rated current and C tripping curve. The Icn rated short circuit breaking capacity is up to 6000A at 400VAC conforming to EN/IEC 60898-1 standard. It is compliant with IEC 60898-1 standard. This miniature circuit breaker combines functions of circuit protection against short circuit and overload current, control and isolation. Mechanical durability goes up to 20000 cycles and electrical durability goes up to 10000 cycles. The Ue operational voltage is going from 400VAC. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 6 pitches of 9mm. The product colour is white (RAL9003). The dimensions are (W) 54mm x (H) 81mm x (D) 71.5mm. The weight is 0.285kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -5°C to 60°C. The storage temperature is -40°C to 85°C.
miniature circuit breaker  iK60N  1P  40 A  C curve
Schneider miniature circuit breaker - iK60N - 1P - 40 A - C curve
This Acti9 iK60N product is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole and 40A In rated current and C tripping curve. The rated short circuit breaking capacity goes up to 6000A at 230VAC conforming to EN/IEC 60898-1 standard and at conforming to standard. This product is compliant with EN/IEC 60898-1 standard. This miniature circuit breaker protects circuit against short circuit and overload current. It has a double clip for dismounting with comb busbar in place. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 2 pitches of 9mm. The product colour is white (RAL9003). The dimensions are (W) 18mm x (H) 85mm x (D) 78.5mm. The weight is 100g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C.
miniature circuit breaker  iK60N  2P  40 A  C curve
Schneider miniature circuit breaker - iK60N - 2P - 40 A - C curve
This Acti9 iK60N product is a low voltage miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles and 40A In rated current and C tripping curve. The rated short circuit breaking capacity goes up to 6000A at 230VAC conforming to EN/IEC 60898-1 standard and at conforming to standard. This product is compliant with EN/IEC 60898-1 standard. This miniature circuit breaker protects circuit against short circuit and overload current. It has a double clip for dismounting with comb busbar in place. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 4 pitches of 9mm. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 78.5mm. The weight is 200g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C.
miniature circuit breaker  iK60N  3P  6 A  C curve
Schneider miniature circuit breaker - iK60N - 3P - 6 A - C curve
This Acti9 iK60N product is a low voltage miniature circuit breaker (MCB). It is a 3P circuit breaker with 3 protected poles and 6A In rated current and C tripping curve. The rated short circuit breaking capacity goes up to 6000A at 400VAC conforming to EN/IEC 60898-1 standard and at conforming to standard. This product is compliant with EN/IEC 60898-1 standard. This miniature circuit breaker protects circuit against short circuit and overload current. It has a double clip for dismounting with comb busbar in place. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 400VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 6 pitches of 9mm. The product colour is white (RAL9003). The dimensions are (W) 54mm x (H) 85mm x (D) 78.5mm. The weight is 300g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C.
Masterpact NT external power supply module input voltage 200 V AC to 240 V AC 5060 Hz output voltage 24 V DC output current 1 A
Schneider Masterpact NT external power supply module, input voltage 200 V AC to 240 V AC 50/60 Hz, output voltage 24 V DC, output current 1 A
ComPacT circuit breakers feature Schneider Electric’s exclusive Roto-Active Breaking System; it reduces the effects of short circuits of your installation. Today, the ComPacT range is optimized with a high level of breaking capacities, outstanding selectivity and cascading. It offers more advanced functions and ergonomic designs for easy installation and operations.
MasterPact MTZ  ACB 5000A 3P Micro 20X Electrically Operated
Schneider MasterPact MTZ - ACB 5000A 3P Micro 2.0X Electrically Operated
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.

Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.

The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.
ACB 1000A 3P 100kA
Siemens ACB 1000A 3P 100kA
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.

Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.

The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.
ACB 1000A 3P 85kA
Siemens ACB 1000A 3P 85kA
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.

Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.

The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.
ACB 1000A 3P 55kA
Siemens ACB 1000A 3P 55kA
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.

Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.

The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.
ACB 3200A 3P 66kA
Siemens ACB 3200A 3P 66kA
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.

Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.

The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.
ACB 1250A 4P 55kA
Siemens ACB 1250A 4P 55kA
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.

Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.

The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.