a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Measuring Tools

Fluke Fluke ii915 Acoustic Imager

Fluke ii915 Acoustic Imager: Detect, Locate, and Assess Anomalies

The Fluke ii915 Acoustic Imager is a powerful tool designed to identify and evaluate issues in various systems. With three distinct modes—LeakQ™, PDQ™, and MecQ™—this innovative device empowers maintenance professionals to take proactive measures and prevent costly problems. Let’s explore its capabilities:

Leak Detection with More Sensitivity
LeakQ™ Mode: Detect Hidden Costs


Leaks in compressed air, gas, steam, and vacuum systems can lead to significant financial losses. The Fluke ii915 simplifies leak detection by allowing technicians to visualize sound. As they scan hoses, fittings, and connections, the built-in acoustic array captures decibel levels per frequency. The resulting SoundMap™ overlays on a visual image, making it easy to pinpoint leaks—even during peak operation hours. Say goodbye to time-consuming inspections and hello to efficient leak detection. Fluke ii915 has the high frequency range and best sensitivity to do acoustic leak detection more efficiently.

Early Mechanical Issue Identification
MecQ™ Mode: Efficient Inspection for Conveyor Systems


Conveyor systems are notorious for their complexity and potential to disrupt production. The Fluke ii915 acoustic camera revolutionizes inspection by enabling contactless scanning of large areas. Advanced noise filtering ensures clear images, even in high-noise environments. Detecting potential mechanical issues early allows targeted maintenance, preventing unplanned downtime. For seamless operation and proactive maintenance of large conveyance systems, the Fluke ii915 Acoustic Imager with MecQ™ is the ultimate choice.

Visualizing the Invisible Threat
PDQ™ Mode: Locating Partial Discharge


Partial discharge poses serious risks, from arc flash fires to blackouts. The Fluke ii915 translates partial discharge sounds into visuals, precisely pinpointing their location. With an extended frequency range of 2-100 kHz, this tool can detect partial discharge even earlier and aids maintenance planning to prevent catastrophic events. High-voltage electricians, electrical test engineers, and grid maintenance teams can now see what was once invisible.

Key features
• Enhanced Performance: Improved detection performance for gas leaks, electrical discharges, and mechanical issues.
• LeakQ™ Mode: Estimated leak size and cost.
• PDQ Mode™: Assesses discharge severity.
• MecQ™ Mode: Proactively address potential problems in rotating mechanical components.
• Reporting Features: Integrated visual and textual tagging and annotation functionalities for streamlined reporting.
• Wireless Upload: Easily transfer data to Fluke Connect.
Download
Produk Lainnya
5130mm VERNIER CALIPER
Kennedy 5"/130mm VERNIER CALIPER
Metric & Inch Reading - Graduation: 0.02mm/0.001"

Incorporating Quadri feature - gives outside, inside, depth and step readings.

Fine adjustment feature allows improved sensitivity of slider movement.

14° vernier face angle reduces parallax.



Satin chrome finish with clear easy read graduations.
715 VoltmA Loop Calibrator
Fluke 715 Volt/mA Loop Calibrator
The Fluke 715 Volt/ mA Calibrator provides outstanding performance, durability and reliability. Offered in the rugged Fluke 80 Series DMM package, the calibrator is compact, lightweight and easy to transport. With a push button interface similar to the multifunctional Fluke 740 Series Documenting , the 715 is easy to use. It is EMI, dust, splash proof and has a removable battery cover for quick battery changes.
9040 Phase Rotation Indicator
Fluke 9040 Phase Rotation Indicator
• 3 phase indication

• Indication of phase rotation

• Clear LCD display

• No battery required
729 Automatic Pressure Calibrator
Fluke 729 Automatic Pressure Calibrator
Automatically generates and controls pressure up to 300 psi (20 bar, 2 MPa). Enter the pressure and the 729 will automatically pump to the desired pressure. Fill out the test template and the 729 will automatically pump and document pressure calibration tests at multiple points.



Easy calibration documentation using predefined templates for transmitters and switches. Enter the initial and final test pressures and the number of test points. The rest of the 729 did by documenting the applied pressure, the measured mA, and the % error of each test point. The bright color graphics display will highlight the tolerance test results in red.



Automatic fine adjustment of internal pressure helps compensate for minor leaks in hoses and test settings. There is no need to manually turn the vernier to check for leaks, helping to eliminate the hassle of manual pumping and manual fine adjustment of test settings.



HART communication allows trimming of mA output, trimming to applied value, and trimming to zero pressure from HART pressure transmitters. You can also perform light configuration tasks such as changing transmitter tags, units of measurement, and setting ranges. Other supported HART commands include setting a fixed mA output for troubleshooting, reading device configurations and variables, and reading device diagnostics.



Measures mA signal at transmitter source output and simulates mA signal for testing I/Ps and other mA loop devices. Includes a 24V loop power supply to test and power transmitters in self-tests not connected to a control system.



Rugged portable case design 3 year warranty sets the 729 apart from most other pressure calibrators. The 729 is tested and guaranteed to withstand a 1 meter drop test, making it ready for field instrumentation calibration work.



Fluke Connect® compatibility allows users to remotely monitor using the Fluke Connect mobile app as well as manage and store pressure measurements and log events. Share measurements using ShareLive™ video calls and email.



Measure temperature with the optional 720RTD probe to perform resistance transfer calibration.



Measure pressure with the old 700 Series and new 750 Series pressure modules if a different pressure measurement range or resolution is desired.



Multiple language support : select the language from the instrument setup utility. Hart communication commands are limited to English per HART device description and protocol.



The rigid yet flexible carrying case is designed for field work, with room in the bag for storing, test hoses, fittings, test cables and small tools needed for field pressure calibration.



Portable automatic pressure calibrator makes pressure calibration easy



The Fluke 729 Automatic Pressure Calibrator has been specifically designed with the work of process technicians in mind to simplify the pressure calibration process and provide faster, more accurate test results. Technicians know that calibrating pressure is a time-consuming task, but the 729 makes it easier than ever with an internal electric pump that generates and adjusts pressure automatically in a rugged, easy-to-use portable package.



The 729's ideal portable pressure calibrator, allows you to simply enter a target pressure, and the calibrator will pump automatically at the desired set point. Then, an internal fine adjustment control automatically stabilizes the pressure at the set value.



The Fluke 729 can also test multiple pressure test points automatically and automatically document the results. Calibration is as simple as entering the initial and final pressures as well as the number of test points and tolerance levels. The remaining 729 do.



Built-in HART communication capability allows for mA tuning of HART transmitters, lightweight HART configuration, and the ability to adjust to applied 0% and 100% values.



Upload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easier to manage your instrumentation, create scheduled tests and reports, and manage calibration data.



With three selectable ranges, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa), and 300 psi (20 bar, 2 MPa), the Fluke 729 Automatic Pressure Calibrator is designed to work anytime, anywhere. wherever you need it.



30 psi range, 2 bar, no wireless communication