Fluke 376 True-rms AC/DC Clamp Meter dengan iFlex

Get ready for anything.



The Fluke 376 Clamp Meter offers improved performance for a wide range of flow size situations. With true-rms voltage and current rating, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes.



In addition, the Fluke 376 includes an iFlex™ flexible current probe that extends the measuring range to 2500 A ac while providing increased display flexibility, the ability to measure odd-sized conductors and increased cable access. The Fluke 376 is a direct replacement for the Fluke 337 Clamp Meter.



Download
Produk Lainnya
Fluke FEV100 Electric Vehicle Charging Station EVSE Test Adapter
Fluke Fluke FEV100 Electric Vehicle Charging Station EVSE Test Adapter
Test the safety and performance of a type 1, level 1 or level 2 electric vehicle ac charging stations (EVSEs) with the Fluke FEV100. This test adapter simulates the presence of an electrical vehicle, allowing you to conduct tests in combination with appropriate test instruments such as a digital multimeter or oscilloscope. Use the FEV100 to verify an EVSE is working properly after install and during periodic maintenance, or troubleshoot an EVSE if it is not delivering the appropriate charge.
Electrical safety
EVSE charging cables may become damaged over the course of use, increasing electric shock risks to users. Stay protected from and check risk of electric shock with the GFCI trip test. This function verifies the breaker of the EVSE is connected by detecting ground faults. Additionally, the PE grounding protection pre-test verifies that there is no presence of dangerous voltage at the ground terminal.
Simplicity and convenience
Perform a variety of tests including ground fault checks, insulation of wires, measuring voltage and duty cycle to see max current available for charging all in one adapter that safely integrates with the Fluke portfolio of test and measurement tools. There is no need to bring an electric vehicle onsite for EVSE troubleshooting: the adapter acts as an electric vehicle when connected to an EVSE for easy performance and maintenance testing.
Recommended tools for use with the FEV100

Key features
• Check protective earth for correct wiring and functioning with the PE pre-test feature.
• Perform GFCI troubleshooting of EVSE and verify operation within safety standards.
• Test charging states of EVSE with CP state simulation.
• Verify charging voltage and maximum available current using a multimeter.
• SAE J1772 compliant to North American standards.
729 Automatic Pressure Calibrator
Fluke 729 Automatic Pressure Calibrator
Automatically generates and controls pressure up to 300 psi (20 bar, 2 MPa). Enter the pressure and the 729 will automatically pump to the desired pressure. Fill out the test template and the 729 will automatically pump and document pressure calibration tests at multiple points.



Easy calibration documentation using predefined templates for transmitters and switches. Enter the initial and final test pressures and the number of test points. The rest of the 729 did by documenting the applied pressure, the measured mA, and the % error of each test point. The bright color graphics display will highlight the tolerance test results in red.



Automatic fine adjustment of internal pressure helps compensate for minor leaks in hoses and test settings. There is no need to manually turn the vernier to check for leaks, helping to eliminate the hassle of manual pumping and manual fine adjustment of test settings.



HART communication allows trimming of mA output, trimming to applied value, and trimming to zero pressure from HART pressure transmitters. You can also perform light configuration tasks such as changing transmitter tags, units of measurement, and setting ranges. Other supported HART commands include setting a fixed mA output for troubleshooting, reading device configurations and variables, and reading device diagnostics.



Measures mA signal at transmitter source output and simulates mA signal for testing I/Ps and other mA loop devices. Includes a 24V loop power supply to test and power transmitters in self-tests not connected to a control system.



Rugged portable case design 3 year warranty sets the 729 apart from most other pressure calibrators. The 729 is tested and guaranteed to withstand a 1 meter drop test, making it ready for field instrumentation calibration work.



Fluke Connect® compatibility allows users to remotely monitor using the Fluke Connect mobile app as well as manage and store pressure measurements and log events. Share measurements using ShareLive™ video calls and email.



Measure temperature with the optional 720RTD probe to perform resistance transfer calibration.



Measure pressure with the old 700 Series and new 750 Series pressure modules if a different pressure measurement range or resolution is desired.



Multiple language support : select the language from the instrument setup utility. Hart communication commands are limited to English per HART device description and protocol.



The rigid yet flexible carrying case is designed for field work, with room in the bag for storing, test hoses, fittings, test cables and small tools needed for field pressure calibration.



Portable automatic pressure calibrator makes pressure calibration easy



The Fluke 729 Automatic Pressure Calibrator has been specifically designed with the work of process technicians in mind to simplify the pressure calibration process and provide faster, more accurate test results. Technicians know that calibrating pressure is a time-consuming task, but the 729 makes it easier than ever with an internal electric pump that generates and adjusts pressure automatically in a rugged, easy-to-use portable package.



The 729's ideal portable pressure calibrator, allows you to simply enter a target pressure, and the calibrator will pump automatically at the desired set point. Then, an internal fine adjustment control automatically stabilizes the pressure at the set value.



The Fluke 729 can also test multiple pressure test points automatically and automatically document the results. Calibration is as simple as entering the initial and final pressures as well as the number of test points and tolerance levels. The remaining 729 do.



Built-in HART communication capability allows for mA tuning of HART transmitters, lightweight HART configuration, and the ability to adjust to applied 0% and 100% values.



Upload and manage documented calibration results with DPCTrack2™ Calibration Management Software, making it easier to manage your instrumentation, create scheduled tests and reports, and manage calibration data.



With three selectable ranges, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa), and 300 psi (20 bar, 2 MPa), the Fluke 729 Automatic Pressure Calibrator is designed to work anytime, anywhere. wherever you need it.



30 psi range, 2 bar, no wireless communication
12300mm DIGITAL ABS ELECTRONIC CALIPER
Kennedy 12"/300mm DIGITAL ABS ELECTRONIC CALIPER
Modern design with a knurled thumb wheel for easy use when taking internal and external depth and step measurements.

Dual readout giving instant inch/metric conversion at the touch of a button.

Zero reset at any point, large clear display, error-free operation, fast response speed. Non-output type.



Resolution: 0.01mm/0.0005".



Extra batteries available - Order Code EDI -904-4000K.



726 Precision Multifunction Calibrators
Fluke 726 Precision Multifunction Calibrators
Process calibration designed specifically for process industries



The Fluke 726 is a precise and powerful, yet easy-to-use, field calibrator. It features broad workload coverage, calibration power, and unsurpassed accuracy needed by process professionals. It measures and sources almost all process parameters to calibrate almost anything. Use it to test sensors and valves, and to test and calibrate transmitters. The 726 interprets results without the help of a calculator and stores measurement data for later analysis.



Measurement capabilities



This precision multifunction calibrator measures volts, mA, pressure, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters. The 726 also sources and simulates volts, mA, thermocouples, RTDs, frequency to calibrate transmitters. Measures and/or sources pressure using when paired with any of the 50 Fluke 750P series Pressure Modules to test and calibrate pressure transmitters and other devices. The 726 can also:

- Source mA with simultaneous pressure measurement to conduct valve and I/P test

- Conduct enhanced flowmeter testing with frequency totalizer and frequency pulse train source mode



Designed for ease of use



The 726 has built-in features that make it easier to use in nearly any measurement situation. From its ability to store frequently used test setups, to programming custom RTD probe calibration constants for enhanced temperature measurement, or the integrated voltage input protection design that improves reliability, the 726 is built to perform. The use of two separate channels even allows you to measure, source, or view process signals simultaneously. The backlit display provides better visibility in low-light conditions, and the standard 3-year warranty provides extra confidence that the 726 will be there when you need it to be.



You can also use the 726 to:

- Capture the set, reset, and deadband of a pressure switch with the integrated switch test

- Calculate the transmitter error % to interpret calibration results without the use of a calculator

- Perform fast linearity tests with the auto-step and auto-ramp features

- Power a transmitter during test using 24 V loop supply and simultaneous mA measurement