a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Electrical & Lighting

Schneider miniature circuit breaker - iK60N - 1P - 40 A - C curve

This Acti9 iK60N product is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole and 40A In rated current and C tripping curve. The rated short circuit breaking capacity goes up to 6000A at 230VAC conforming to EN/IEC 60898-1 standard and at conforming to standard. This product is compliant with EN/IEC 60898-1 standard. This miniature circuit breaker protects circuit against short circuit and overload current. It has a double clip for dismounting with comb busbar in place. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The operating frequency is 50Hz or 60Hz. It can be mounted on DIN rail for modular installation. Its width is 2 pitches of 9mm. The product colour is white (RAL9003). The dimensions are (W) 18mm x (H) 85mm x (D) 78.5mm. The weight is 100g. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C.
Download
Produk Lainnya
ACB 1000A 3P 85kA
Siemens ACB 1000A 3P 85kA
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.

Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.

The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.
NNP19940031
Panasonic NNP19940031
Type of Luminaire : Standard Floodlight (Pro) A Series
Set Model No : NNP19940031
Type of Light Source : LED
Power Input : 120W
System Lumen Output : 15600 lm
Power Voltage : 110-240V
Lifetime : 50000H(L70)
CCT : 5000K
CRI : 70
Input Frequency : 50/60Hz
Dimming : non-Dimmable
Glare Cut Angle : 60deg.
Beam Angle : 60deg.
IP Rating : 65
Ambient Temperature : -40 - 50°C
Dimensions : 304mmx310mmx296mm
Body : ADC
NYV20104BE1A
Panasonic NYV20104BE1A
Type of Luminaire : High Efficacy/Standard High Bay
Set Model No : NYV20104BE1A
Type of Light Source LED
Power Input : 200W
System Lumen Output : 28570 lm
System Efficacy : 143 lm/W
Power Voltage : 220-240V
Power Factor : 0.95
Lifetime : 50000H(L70)
CCT : 4000K
CRI : 80
Input Frequency : 50/60Hz
Dimming : non-Dimmable
Beam Angle : 60deg.
IP Rating : 65
Ambient Temperature : -30 - 50°C
Surge Protection : 10kVA
Dimensions : 320mmx172mm
Weight : 3.9 kg
Body : ADC(Black)
M12 LED Stand Light
Milwaukee M12™ LED Stand Light
M12 SAL-0
• Light head rotates 210° and pivots 270° for light in any direction
• Collapses down to 78cm with three side handles for easy transportation and storage
• Sets up in 5 seconds, Three height positions; 90cm, 127cm & 173cm