a a a a a a a a a a a a
Distributor Fluke
Distributor Fluke
Customer Services
(021) 2908-5810
/
628111042805
Electrical & Lighting

Panasonic NYV20155BE2A

Type of Luminaire : High Efficacy/Standard High Bay
Set Model No : NYV20155BE2A
Type of Light Source LED
Power Input : 75W
System Lumen Output : 10710 lm
System Efficacy : 143 lm/W
Power Voltage : 220-240V
Power Factor : 0.95
Lifetime : 50000H(L70)
CCT : 5000K
CRI : 80
Input Frequency : 50/60Hz
Dimming : non-Dimmable
Beam Angle : 60deg.
IP Rating : 65
Ambient Temperature : -30 - 50°C
Surge Protection : 10kVA
Dimensions : 240mmx166mm
Weight : 1.99 kg
Body : ADC(Black)
Download
Produk Lainnya
NYV20104BE1A
Panasonic NYV20104BE1A
Type of Luminaire : High Efficacy/Standard High Bay
Set Model No : NYV20104BE1A
Type of Light Source LED
Power Input : 200W
System Lumen Output : 28570 lm
System Efficacy : 143 lm/W
Power Voltage : 220-240V
Power Factor : 0.95
Lifetime : 50000H(L70)
CCT : 4000K
CRI : 80
Input Frequency : 50/60Hz
Dimming : non-Dimmable
Beam Angle : 60deg.
IP Rating : 65
Ambient Temperature : -30 - 50°C
Surge Protection : 10kVA
Dimensions : 320mmx172mm
Weight : 3.9 kg
Body : ADC(Black)
MasterPact MTZ  ACB 5000A 3P Micro 20X Electrically Operated
Schneider MasterPact MTZ - ACB 5000A 3P Micro 2.0X Electrically Operated
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.

Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.

The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.
NYS12727LD2031
Panasonic NYS12727LD2031
Type of Luminaire : Standard Floodlight (Pro) A Series
Set Model No : NYS12727LD2031
Type of Light Source : LED
Power Input : 706W
System Lumen Output : 106700 lm
Power Voltage : 200-242V
Lifetime : 40000H(L70)
CCT : 5000K
CRI : 70
Input Frequency : 50/60Hz
Dimming : non-Dimmable
Glare Cut Angle : 64deg.
Beam Angle : 75deg.
IP Rating : 65
Ambient Temperature : -20 - 35°C
Dimensions : 487mmx537mmx720mm
Body : ADC
ACB 1250A 4P 55kA
Siemens ACB 1250A 4P 55kA
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.

Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.

The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.