Type of Luminaire : High Efficacy/Standard High Bay Set Model No : NYV20102BE1A Type of Light Source LED Power Input : 140W System Lumen Output : 20000 lm System Efficacy : 143 lm/W Power Voltage : 220-240V Power Factor : 0.95 Lifetime : 50000H(L70) CCT : 4000K CRI : 80 Input Frequency : 50/60Hz Dimming : non-Dimmable Beam Angle : 60deg. IP Rating : 65 Ambient Temperature : -30 - 50°C Surge Protection : 10kVA Dimensions : 280mmx172mm Weight : 2.8 kg Body : ADC(Black)
Type of Luminaire : Smart Street Light Set Model No : NSP10460LR Type of Light Source : LED Power Input : 60W System Lumen Output : 9000 lm System Efficacy : 150 lm/W Lifetime : 50000H(L70) CCT: 5000K CRI : 70 Dimming : non-Dimmable Glare Cut Angle : 32deg. Beam Angle : 117deg. IP Rating : 66 Ambient Temperature : 5 - 40°C Dimensions : 625mmx1944mmx269mm Body : ADC & Aluminium Extrution
Type of Luminaire : Standard Floodlight (Pro) A Series Set Model No : NYS12747LD2031 Type of Light Source : LED Power Input : 661W System Lumen Output : 103400 lm Power Voltage : 200-242V Lifetime : 40000H(L70) CCT : 5000K CRI : 70 Input Frequency : 50/60Hz Dimming : non-Dimmable Glare Cut Angle : 54deg. Beam Angle : 34deg. IP Rating : 65 Ambient Temperature : -20 - 35°C Dimensions : 487mmx537mmx720mm Body : ADC
Type of Luminaire : Standard Floodlight (Pro) A Series Set Model No : NYS12727LD2031 Type of Light Source : LED Power Input : 706W System Lumen Output : 106700 lm Power Voltage : 200-242V Lifetime : 40000H(L70) CCT : 5000K CRI : 70 Input Frequency : 50/60Hz Dimming : non-Dimmable Glare Cut Angle : 64deg. Beam Angle : 75deg. IP Rating : 65 Ambient Temperature : -20 - 35°C Dimensions : 487mmx537mmx720mm Body : ADC
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.
Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.
The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.