Type of Luminaire : Smart Street Light Set Model No : NSP10460LR Type of Light Source : LED Power Input : 20W System Lumen Output : 3000 lm System Efficacy : 150 lm/W Lifetime : 50000H(L70) CCT: 5000K CRI : 70 Dimming : non-Dimmable Glare Cut Angle : 32deg. Beam Angle : 117deg. IP Rating : 66 Ambient Temperature : 5 - 40°C Dimensions : 434mmx896mmx269mm Body : ADC & Aluminium Extrution
Type of Luminaire : Standard Floodlight (Pro) A Series Set Model No : NYS12337LD2031 Type of Light Source : LED Power Input : 267W System Lumen Output : 40400 lm Power Voltage : 200-242V Lifetime : 40000H(L70) CCT : 5000K CRI : 70 Input Frequency : 50/60Hz Dimming : non-Dimmable Glare Cut Angle : 64deg. Beam Angle : 53deg. IP Rating : 65 Ambient Temperature : -20 - 35°C Dimensions : 422mmx534mmx340mm Body : ADC
Type of Luminaire : Smart Street Light Set Model No : NSP10460LR Type of Light Source : LED Power Input : 60W System Lumen Output : 9000 lm System Efficacy : 150 lm/W Lifetime : 50000H(L70) CCT: 5000K CRI : 70 Dimming : non-Dimmable Glare Cut Angle : 32deg. Beam Angle : 117deg. IP Rating : 66 Ambient Temperature : 5 - 40°C Dimensions : 625mmx1944mmx269mm Body : ADC & Aluminium Extrution
Type of Luminaire : High Efficacy/Standard High Bay Set Model No : NYV20102BE1A Type of Light Source LED Power Input : 140W System Lumen Output : 20000 lm System Efficacy : 143 lm/W Power Voltage : 220-240V Power Factor : 0.95 Lifetime : 50000H(L70) CCT : 4000K CRI : 80 Input Frequency : 50/60Hz Dimming : non-Dimmable Beam Angle : 60deg. IP Rating : 65 Ambient Temperature : -30 - 50°C Surge Protection : 10kVA Dimensions : 280mmx172mm Weight : 2.8 kg Body : ADC(Black)
Air Circuit Breaker (ACB) is one type of electrical protection device commonly used in electrical systems. Air Circuit Breaker is an electrical protection device used to cut off the flow of electricity in an electrical circuit when there is a disturbance or excess current. This tool is generally used in industrial electrical panels and can be used in electrical systems with quite high voltage.
Air Circuit Breaker works by cutting off the flow of electricity in an electrical circuit when there is a disturbance or excess current. Air Circuit Breaker uses a special system consisting of several components, such as trip unit, operating mechanism, and current transformer. When there is a disturbance in an electrical circuit, the trip unit will detect excess current. Then, it gives a signal to the operating mechanism to cut off the flow of electricity in the circuit. After the electric current is cut off, Air Circuit Breaker will extinguish the arc that occurs using the arc extinguishing system that has been prepared.
The main function of Air Circuit Breaker is to protect electrical equipment and systems from damage due to over current or excess current, which usually occurs due to short circuit or overload.